Model |
SUN-3.6K-SG03LP1-EU |
SUN-5K-SG03LP1-EU |
SUN-6K-SG03LP1-EU |
Battery Input Data |
|
Battery Type |
Lead-acid or Lithium-ion |
Battery Voltage Range(V) |
40-60 |
Max.Charging Current(A) |
90 |
120 |
135 |
Max.Discharging Current(A) |
90 |
120 |
135 |
Charging Strategy for Li-ion Battery |
Self-adaption to BMS |
Number of battery input |
1 |
PV String Input Data |
|
Max DC Input Power(W) |
4680 |
6500 |
7800 |
Max DC Input Voltage(V) |
500 |
Start-up Voltage(V) |
125 |
MPPT Voltage Range(V) |
150-425 |
Rated DC Input Voltage(V) |
370 |
Max Input Short-Circuit Current(A) |
17+17 |
Max Operating PV Input Current(A) |
13+13 |
No.of MPP Trackers/No.of String Per MPP Tracker |
2/1+1 |
AC Input/Output Data |
|
Rated AC Input/Output Active Power(W) |
3600 |
5000 |
6000 |
Max AC Input/Output Apparent Power (VA) |
3960 |
5500 |
6600 |
Peak Power (off-grid)(W) |
2 times of rated power,10s |
Rated AC Input/Output Current(A) |
16.4/15.7 |
22.7/21.7 |
27.3/26.1 |
Max AC Input/Output Current(A) |
18/17.2 |
25/23.9 |
30/28.7 |
Max Continuous AC Passthrough (grid to load)(A) |
35 |
40 |
Rated Input/Output Voltage/Range(V) |
220V/230 0.85Un-1.1Un |
Grid Connection Form |
L+N+PE |
Rated Input/Output Grid Frequency/Range |
50Hz/45Hz-55Hz 60Hz/55Hz-65Hz |
Power Factor Adjustment Range |
0.8 leading-0.8lagging |
Total Current Harmonic Distortion THDi |
<3% (of nominal power) |
DC Injection Current |
<0.5%ln |
Efficiency |
|
Max Efficiency |
97.60% |
Euro Efficiency |
96.50% |
MPPT Efficiency |
>99% |
Equipment Protection |
|
DC Polarity Reverse Connection Protection |
yes |
AC Output Overcurrent Protection |
yes |
AC Output Overvoltage Protection |
yes |
AC Output Short Circuit Protection |
yes |
Thermal Protection |
yes |
DC Terminal Insulation Impedance Monitoring |
yes |
DC Component Monitoring |
yes |
Ground Fault Current Monitoring |
yes |
Power Network Monitoring |
yes |
Island Protection Monitoring |
yes |
Earth Fault Detection |
yes |
DC Input Switch |
yes |
Overvoltage Load Drop Protection |
yes |
Residual Current (RCD) Detection |
yes |
Surge Protection Level |
TYPE II(DC),TYPE II(AC) |
Interface |
|
Communication Interface |
WIFI,RS485,CAN |
General Data |
|
Operating Temperature Range |
-40 to+60℃,>45℃ Derating |
Permissible Ambient Humidity |
0~100% |
Permissible Altitude |
2000m |
Noise |
<30 dB(A) |
Ingress Protection(IP) Rating |
IP 65 |
Inverter Topology |
Non-Isolated |
Over Voltage Category |
OVC II(DC),OVC III(AC) |
Cabinet size(W*H*D)[mm] |
330×580×232 (Excluding Connectors and Brackets) |
Weight[kg] |
25 |
Warranty |
5 Years/10 Years |
the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy |
Type Of Cooling |
Intelligent air cooling |
Grid Regulation |
IEC 61727,IEC 62116,CEI 0-21,EN 50549,NRS 097,RD 140,UNE 217002,OVE-Richtlinie R25,G99,VDE-AR-N 4105 |
Safety EMC/Standard |
IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |