SUN-6K-SG03LP1-EU Hybrid Inverter

$880

  • Colorful touch LCD, IP65 protection degree
  • AC couple to retrofifit existing solar system
  • Max. 16 pcs parallel for on-grid and off-grid
    operation; Support multiple batteries parallel
  • Max. charging/discharging current of 135A
  • 6 time periods for battery charging/discharging
  • Support storing energy from diesel generator
SKU: SUN-6K-SG03LP1-EU Category:

Description

 Model  SUN-3.6K-SG03LP1-EU  SUN-5K-SG03LP1-EU  SUN-6K-SG03LP1-EU
 Battery Input Data
 Battery Type  Lead-acid or Lithium-ion
 Battery Voltage Range(V)  40-60
 Max.Charging Current(A) 90 120 135
 Max.Discharging Current(A) 90 120 135
 Charging Strategy for Li-ion Battery  Self-adaption to BMS
 Number of battery input 1
 PV String Input Data
 Max DC Input Power(W) 4680 6500 7800
 Max DC Input Voltage(V) 500
 Start-up Voltage(V) 125
 MPPT Voltage Range(V)  150-425
 Rated DC Input Voltage(V) 370
 Max Input Short-Circuit Current(A)  17+17
 Max Operating PV Input Current(A)  13+13
 No.of MPP Trackers/No.of String Per MPP Tracker  2/1+1
 AC Input/Output Data
 Rated AC Input/Output Active Power(W) 3600 5000 6000
 Max AC Input/Output Apparent Power (VA) 3960 5500 6600
 Peak Power (off-grid)(W)  2 times of rated power,10s
 Rated AC Input/Output Current(A)  16.4/15.7  22.7/21.7  27.3/26.1
 Max AC Input/Output Current(A)  18/17.2  25/23.9  30/28.7
 Max Continuous AC Passthrough (grid to load)(A) 35 40
 Rated Input/Output Voltage/Range(V)  220V/230 0.85Un-1.1Un
 Grid Connection Form  L+N+PE
 Rated Input/Output Grid Frequency/Range  50Hz/45Hz-55Hz     60Hz/55Hz-65Hz
 Power Factor Adjustment Range  0.8 leading-0.8lagging
 Total Current Harmonic Distortion THDi  <3% (of nominal power)
 DC Injection Current  <0.5%ln
 Efficiency
 Max Efficiency 97.60%
 Euro Efficiency 96.50%
 MPPT Efficiency  >99%
 Equipment Protection
 DC Polarity Reverse Connection Protection  yes
 AC Output Overcurrent Protection  yes
 AC Output Overvoltage Protection  yes
 AC Output Short Circuit Protection  yes
 Thermal Protection  yes
 DC Terminal Insulation Impedance Monitoring  yes
 DC Component Monitoring  yes
 Ground Fault Current Monitoring  yes
 Power Network Monitoring  yes
 Island Protection Monitoring  yes
 Earth Fault Detection  yes
 DC Input Switch  yes
 Overvoltage Load Drop Protection  yes
 Residual Current (RCD) Detection  yes
 Surge Protection Level  TYPE II(DC),TYPE II(AC)
 Interface
 Communication Interface  WIFI,RS485,CAN
 General Data
 Operating Temperature Range  -40 to+60℃,>45℃ Derating
 Permissible Ambient Humidity  0~100%
 Permissible Altitude  2000m
 Noise  <30 dB(A)
 Ingress Protection(IP) Rating  IP 65
 Inverter Topology  Non-Isolated
 Over Voltage Category  OVC II(DC),OVC III(AC)
 Cabinet size(W*H*D)[mm]  330×580×232 (Excluding Connectors and Brackets)
 Weight[kg] 25
 Warranty  5 Years/10 Years
 the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy
 Type Of Cooling  Intelligent air cooling
 Grid Regulation  IEC 61727,IEC 62116,CEI 0-21,EN 50549,NRS 097,RD 140,UNE 217002,OVE-Richtlinie R25,G99,VDE-AR-N 4105
 Safety EMC/Standard  IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2

Additional information

Weight 25 kg
Dimensions 78.9 × 49 × 35.7 cm